| Standard Aluminum Entrance Door |
Insulated or non-insulated aluminum stiles and rails with single- or insulating-glass infill. |
Commercial buildings, schools, offices, retail entrances, and public facilities. |
Approximately 0.50–1.20, depending strongly on glazing, panel design, and thermal breaks. |
ASTM E283 reports air leakage in cfm/ft² at a specified pressure difference. A commonly used fenestration benchmark is ≤0.30 cfm/ft² at 1.57 psf, where applicable. |
Water penetration is not measured by ASTM E283. ASTM E331 or ASTM E547 is commonly used; project requirements often begin around 2.86 psf for exterior commercial doors. |
| Thermally Broken Aluminum Door |
Aluminum frame sections separated by a low-conductivity polyamide or equivalent thermal barrier. |
Energy-conscious commercial buildings, multifamily projects, offices, and conditioned entrances. |
Approximately 0.35–0.80, depending on glazing type, frame depth, and panel insulation. |
A representative target is ≤0.30 cfm/ft² at 1.57 psf; tested performance depends on weatherstripping, corner joints, hardware, and installation. |
ASTM E331 or ASTM E547 may be specified at 2.86 psf or higher for exposed locations. The required pressure must be established by the project specification. |
| Aluminum Storefront Door |
Narrow aluminum frame integrated with a storefront glazing system; commonly center-hung or butt-hinged. |
Low- to medium-rise retail, offices, clinics, restaurants, and interior vestibules. |
Approximately 0.60–1.20, with single glazing producing higher heat transfer than insulating glazing. |
Air leakage is evaluated with ASTM E283 at the pressure stated in the test report. Gasket condition, door sweep, and adjustment have a major effect on results. |
Many storefront systems have limited pressure-rated water performance unless specifically engineered and tested. ASTM E331 or E547 results should be requested. |
| Aluminum Sliding Door |
Sliding panels with aluminum rails, rollers, interlocks, seals, and fixed or operable glazed panels. |
Patios, balconies, residential entrances, hospitality spaces, and large glazed openings. |
Approximately 0.30–0.80 for thermally improved systems; basic systems may be higher. |
Sliding systems are tested for air leakage using ASTM E283. A commonly referenced maximum for operable fenestration is 0.30 cfm/ft² at 1.57 psf, subject to the applicable product standard. |
Water testing is typically performed under ASTM E331 or E547. Drainage tracks and weep holes are essential to the tested water performance. |
| Aluminum Folding or Bi-Fold Door |
Multiple hinged aluminum panels connected by hardware, rollers, seals, and a folding track system. |
Restaurants, event spaces, residential living areas, hospitality projects, and wide openings. |
Approximately 0.35–0.90, varying with panel size, glazing, thermal breaks, and the number of joints. |
ASTM E283 testing measures leakage through panel joints, gaskets, frame corners, and meeting stiles. Multi-panel configurations generally require careful sealing and adjustment. |
ASTM E331 or E547 is used for water penetration. Performance is highly dependent on sill design, panel alignment, and the specified test pressure. |
| Aluminum Full-Panel Door |
Insulated aluminum sheet or composite panel with perimeter rails, stiles, hinges, and perimeter seals. |
Service rooms, utility areas, loading zones, back-of-house spaces, and locations requiring privacy. |
Approximately 0.40–0.90, depending on panel insulation and frame construction. |
A complete assembly may be tested to ASTM E283. Leakage commonly occurs at the perimeter gasket, threshold, corners, and hardware cutouts. |
Water resistance is evaluated separately under ASTM E331 or E547 when exterior exposure requires it; thresholds and sill pans influence results. |
| Aluminum Automatic Entrance Door |
Sliding, swinging, or revolving aluminum door assembly with sensors, operators, safety controls, and seals. |
Airports, hospitals, offices, retail buildings, transit facilities, and high-traffic entrances. |
Approximately 0.50–1.20, depending on the operating type, glazing, frame, and required clearances. |
ASTM E283 can quantify leakage for the installed door assembly, but automatic operating clearances and moving seals may affect the result. |
ASTM E331 or E547 may be specified for exterior assemblies. Automatic doors require compatible sill drainage and weather-seal detailing. |