Engineering Authority · OEM/ODM Fire Barrier Systems

Custom OEM Aluminium Fire Doors Manufacturers & Factories

Engineered high-performance architectural glazing and certified fire-rated barrier assemblies for global commercial developments and luxury estates.

Architectural Fire-Rated & Structural Aluminium Systems

Precision-engineered profiles built from 6063-T6/6060-T6 structural aluminium, designed to integrate seamlessly into modern façades requiring certified fire protection, high acoustic isolation, and weather resistance.

Engineering Integrity: Custom OEM Fire-Rated Aluminium Door Systems

In high-density commercial developments, hospitality projects, and modern mixed-use towers, passive fire protection must perform flawlessly without compromising architectural aesthetics. Specifying custom OEM aluminium fire doors requires balancing structural aluminium alloys, intumescent thermal breaks, ceramic fire glass, and perimeter seals under intense temperatures exceeding 1000°C. DERCHI (Guangdong Dejiyoupin Doors and Windows Co., Ltd.) operates a specialized fabrication division dedicated to building fire-rated entry assemblies, pivot systems, and commercial curtain barriers that satisfy stringent international building codes including EN 1634-1, EN 13501-2, UL 10C, and BS 476-22.

Unlike standard architectural aluminium that softens rapidly when exposed to fire, our OEM composite assemblies incorporate specialized internal fire-core materials, reinforced steel bracket armatures, and patented multi-chamber ceramic silicate cooling fills. These design enhancements limit thermal transfer, prevent structural frame deflection, and restrict smoke migration along critical escape routes.

180,000
Sq.M Manufacturing Base
25+
Years Technical Heritage
600+
Engineers & Tech Staff
30+
Patents & Certifications

Classifications: Integrity (E) vs Insulation (EI)

Specifiers must distinguish between Class E (Integrity) and Class EI (Integrity & Insulation). Class E prevents flames and hot toxic gases from breaching the door envelope, while Class EI incorporates fire-rated intumescent gel interlayers within laminated glazing panels to control radiant heat transfer. In European and high-tier global standards, Class EI (EI30, EI60, EI90, EI120) is essential for fire stairwells, server rooms, and luxury escape corridors, ensuring the unexposed surface remains below a safe average temperature rise of 140°C above ambient.

DERCHI Enterprise Strengths: Why Turnkey Contractors Partner With Us

Decades of continuous fabrication in Foshan, verified by international testing authorities, allow us to offer comprehensive design-build capabilities for major architectural projects.

CE & Global Code Adherence

Fully compliant with EN 14351-1, EN 1634-1, AS 2047, and ISO 9001 certified manufacturing controls. We furnish full technical test dossiers and declarations of performance to support approvals by local building authorities.

Free CAD & BIM Custom Engineering

Our in-house technical office reviews architectural schedules and provides complimentary CAD shop drawings, connection details, and structural thermal calculations before metal processing begins.

One-Stop Architectural Envelope

Beyond fire-rated door assemblies, we produce precision-matched curtain walls, ultra-narrow alloy sliders, stainless security doors, and high-performance bifold windows, lowering consolidation and logistics costs.

CET & Dedicated Timezone Support

Our multilingual project managers and façade engineers operate across UK, CET, and Western time zones, offering timely consultation, drawing markups, and remote field installation oversight.

Schüco Partner Project Proven

Chosen by leading European construction firms and British builders who work with German Schüco systems for multi-villa developments. Our tolerances and anodized finishes match premier European engineering standards.

Reinforced Export Logistics

Custom crating with reinforced multi-layer moisture barriers and steel-banded marine-grade plywood ensures damage-free deliveries directly to major ports including Rotterdam, Hamburg, Antwerp, and Felixstowe.

Architectural Specification Matrix: Aluminium Fire Door Systems

Evaluate achievable engineering thresholds across our custom OEM product line to align with local building control regulations.

Performance Attribute Standard Reference Achievable Range / Rating OEM Structural Construction Detail
Fire Resistance (EI Rating) EN 1634-1 / BS 476-22 EI30, EI60, EI90, EI120 mins Multi-chamber aluminium profile filled with fire-resistant ceramic paste; high-expansion intumescent seals.
Glazing Integrity EN 1363-1 / ISO 834 Laminated / Toughened Fire Glass Multi-layer clear float glass interleaved with intumescent fire gel, turning opaque and insulating during fire events.
Thermal Transmittance (Ud) EN ISO 10077-1/-2 Ud down to 0.85 W/(m²·K) Polyamide PA66 GF25 thermal break bar integrated with high-density polyurethane insulation cores.
Burglar & Intrusion Resistance EN 1627 - RC2 / RC3 / RC4 Up to Class RC3 / RC4 Multi-point motorized or mechanical automatic deadbolt locking, anti-drill plates, and high-tensile alloy reinforcement.
Air & Water Permeability EN 12207 / EN 12208 Class 4 (Air) / Class 9A (Water) Continuous EPDM vulcanized sealing gaskets paired with specialized automatic drop-down mechanical thresholds.
Acoustic Attenuation (Rw) EN ISO 717-1 Rw 38 dB to 48 dB Heavy sound-dampening acoustic composite infill panels combined with asymmetric laminated fire glass options.

Future Sourcing & Procurement Trends in Fire Doors

Architects, facade consultants, and general contractors are adapting to shifting regulatory frameworks, sustainability targets, and smart building integration.

Frequently Asked Questions: OEM Aluminium Fire Door Procurement

Clear guidance for commercial procurement managers, façade consultants, and general contractors.

What is the difference between standard architectural aluminium doors and certified fire-rated aluminium doors?
Standard aluminium doors soften around 550°C to 650°C, failing structural loads within 10 to 15 minutes of direct fire exposure. Certified fire-rated aluminium doors use multi-chamber internal steel reinforcements, fire-resistant ceramic or silicate core compounds, and intumescent gaskets. When exposed to heat, the gaskets expand to block hot smoke and drafts, preserving structural integrity (Class E) and radiant thermal insulation (Class EI) for up to 120 minutes under EN 1634-1 or UL 10C.
Can we order custom dimensions, oversized pivot configurations, and bespoke RAL finishes?
Yes. Our OEM manufacturing facility can fabricate custom door dimensions up to 3.8 meters in height for pivot and hinged systems. Finishes include Qualicoat-certified architectural powder coating in any standard RAL color, fluorocarbon PVDF for severe coastal climates, and authentic wood-grain sublimations. All custom layouts receive detailed CAD shop drawing approvals before profile extrusion and milling.
How does DERCHI verify third-party compliance for building control inspectors?
Every production run includes documentation matching the approved door schedule: certified factory production control (FPC) audit reports, CE marking credentials under EN 14351-1 / EN 16034, ISO 9001 quality certificates, and official laboratory test reports for fire resistance, acoustic performance, and air/water infiltration. We also provide stamped fabrication plans to assist local building control sign-offs.
What is the standard production lead time and sea freight schedule for export orders?
Typical manufacturing lead times range from 25 to 35 calendar days following CAD drawing sign-off and finish confirmation. Products are packaged in reinforced, fumigated marine plywood crates with protective foam corner wraps and humidity-absorbing desiccant. Ocean transit from the Port of Nansha/Shenzhen typically takes 24 to 32 days to Northern European ports (such as Rotterdam, Hamburg, or Felixstowe) and 18 to 22 days to the US West Coast.
Can smart access control, electromagnetic hold-opens, and panic hardware be pre-installed at the factory?
Yes. Our CNC machining centers mill lock pockets, raceways, and hinge recesses according to your hardware schedule. We can install and test electromagnetic door releases, multi-point motorized locks, emergency push exit bars (EN 1125 / UL listed), and door position monitoring sensors before crating, significantly reducing installation labor on site.

Request an Engineered OEM Fire Door Proposal

Send us your door schedules, target performance ratings, or architectural drawings. Our technical engineering desk will prepare CAD shop reviews, thermal analysis, and competitive factory-direct pricing within 24 hours.

Contact Us